Agilent 34970a data acquisition switch unit family product overview 34970a 34972a agilent performance at a fraction of the cost of other standalone data acquisition systems 3slot mainframe with builtin 6. Hi all, i am attempting to connect a 34970a unit to one of several laptops via the rs232 output and an rs232 to usb converter keyspan usa19hs. Automating keysight instruments with labview episode 1 getting. Benchvue gives you an intuitive interface for test configuration and realtime data display and analysis. Its a data logger configured with a 20channel relay multiplexer, the 34970a34972a becomes a powerful, lowcost data logger for simple characterization applications. Thousands of instrument drivers, including the driver for the agilent 34970a, are available for free download from ni.
I have installed pyvisa, agilent connection expert as well. Cleanup the initialization portion consists of getting a handle to the pna and then doing a gpib clear of the pna. Automating an agilent 34411a with labview nxg youtube. Instrument drivers utilize a set of commands provided by the instrument vendor to communicate with the instrument, often through gpib, serial, ethernet, or usb. Ade, driver type, interfaces, options, ni certified, rating.
Agilent 34970 data acquisition system national instruments. Jul 02, 2018 is it compatiable ni gpibusbhs with agilent 34970a data acquisition. If you are looking for drivers for ni products, visit ni drivers. Is it compatiable ni gpibusbhs with agilent 34970a data acquisition. Jan 23, 2020 if you do not need to have the ni and keysight gpib boards in the machine at the same time, but wish to have both drivers installed, refer to use keysight hp agilent gpib devices with ni software. The application of labview in data acquisition system of. The table below shows the general environmental requirements for this instrument.
Additional information nivisa will assign a keysight gpib controller a visa interface name of gpib, where n is the trailing number of the standard instrument control library sicl name assigned by the keysight io configuration utility. I would like to here your recommendation about this subject. Using the agilent 34970a with labview national instruments. Learn how labview can help you control and automate your agilent 34970a. Message 7 of if certain parameters values are known, you should enter them directly e. Jan 20, 2020 home agilent 34970a gpib driver download january 20, 2020 by admin port devices national instruments provides a free labview instrument driver for the a, which gives you programmatic control over the unit from your pc, while having to do little or no programming yourself. Instrument driver network idnet find, download, or submit a driver to communicate with thirdparty instruments. Standard acv accuracy rs232 and gpib interfaces and scpi program.
Dec 18, 2006 i am trying to acquire temperature measurement through a 4w rtd with agilent 34970a. Solution to use the ni visa drivers and both keysight hp agilent and ni gpib devices, you will need to enable nivisatulip. Can i use the national instruments 34970a labview driver and examples with the 34972a. The keysight 34970a data acquisition data logger switch unit consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter. If the sicl name does not have a trailing number, the n will be assigned from the logical unit number assigned by the configuration utility. Keysight 34972a lxi data acquisitionswitch unit testequity. Using both ni gpib and keysight hpib controllers in the.
How to establish the connection between 34970a and pc via rs232 cable duration. National instruments provided a free labview instrument driver for the 34970a. I am using an agilent 82357a gpib to usb cable but cannot get labview to connect. Data acquisition from agilent 34970a via usb hardware lava. I want to access agilent device n3301a using python. Yes, there is a new labview driver that supports both the 34972a and the 34970a. The lxi unit can be set up at remote locations and accessed through the web interface 34970a ivi a network 34970a ivi or through the usb port by copying instrument configurations and measurement data results to a usb flash drive. The driver download for labview nxg requires ni package manager. Instrument drivers provide a higherlevel interface that helps to provide a more abstract view of the instrument that is easier to understand. Thousands of instrument drivers, including the driver for the agilent 34970a, are available for free download from. For more information on using the 34970a for data logging applications, see page 6. Then do a search on 34970a to find the 34970a data acquisition unit for labview instrument. Using both ni gpib and keysight hpib controllers in the same.
What software drivers are available for the 34970a and. Refer to using both ni gpib and keysight hpib controllers in the same system to enable nivisatulip. Agilent a ivi driver top freeware programs i understand you can do this using labview. Feb 27, 2017 how to establish the connection between 34970a and pc via rs232 cable duration. Download the driver from the national instruments website. I have installed pyvisa, agilent connection expert as well the code which i used in python is. Agilent usb gpib 82357a problems hi i know you will say you should have bought a ni usb gpib but i bought an agilent 82357a with their 34970a datalogger. Drivers available for this instrument model ade driver type interfaces options ni certified rating. I wanted to use pyvisa to communicate with some lan based instruments a while ago, but it turns out that the ni drivers arent compatible with version 3 of the linux kernel. Apr 18, 20 if it doesnt but does show an other devices selection, click on that and search for a driver. National instruments provides a free labview instrument driver for the a, which gives you programmatic control over the unit from your pc, while having to do little or no programming yourself. Hello, im looking for a java api in order to communicate with agilent instruments 34970a, 34980a throught usb. Connecting to a 34970a with rs232 and connecting to 34972a.
Whats more, the 34972a with its lan and usb interfaces is ideal for. Enables you to communicate with and control external serial hardware from a pxi or pxi express chassis using asynchronous serial interfaces that support a variety of protocols. The keysight 34970a data acquisition data logger switch consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter. Hpvisa and hpsicl are not national instruments drivers. Oct 18, 2019 agilent technologies keysight technologies 3499a. Each channel can be configured independently to measure one of 11 different functions without the added cost or hassles of signalconditioning accessories. Then do a search on 34970a to find the 34970a data acquisition unit for labview instrument driver. Sep 06, 2019 agilent 82357b labview driver download ive attached a screen grab of what i get. Communication with labview and the 34970a is made via usbgpib and the example code that i downloaded from ni instrument driver sites works fine but, i have difficulties in scanning continuously for a certain time, lets say, 2 minutes with 10 ms. Can i use the national instruments 34970a labview driver and. Apr 06, 2020 34970a labview windows vista driver download uploaded on 04062020, downloaded 6 times, receiving a 4. Environmental condition requirement temperature operating condition 0 c to 55 c humidity operating condition. Agilent 82357b labview driver download ive attached a screen grab of what i get. What software drivers are available for the 34970a and where.
Hi, agilent users, im using 34970a with 20channel multiplexer module and try to scan the voltage signal and save the data file using labview 8. Labview is an industrystandard graphical programming environment that can be used to quickly and easily ac. The 34970a 3slot mainframe, which includes a builtin 6. Agilent performance at a fraction of the cost of other. Agilent connection expert seems to know of the existence of the instrument, but when attempting to identify it, returns either one of two errors. The keysight formerly agilent 34970a data acquisition mainframe is a compact, economical, onebox solution for data logging, data acquisition and generalpurpose switching and control applications. If it doesnt but does show an other devices selection, click on that and search for a driver. Jul 31, 2014 learn how to configure the 34970a for rs232 communication. In purpose to connect to gpib port i am using a gpib to usb adapter from national instruments. Keysight 34970a34972a service guide 7 environmental conditions the 34970a34972a is designed for indoor use and in an area with low condensation. Instrument drivers also provide a common framework, so that a test engineer can move quickly, and productively, between instruments without having to learn everything from scratch. On the pc agilent connection expert is used to create a connection with the instrument. Agilent technologies 34970a quick reference manual pdf download. Automating keysight instruments with labview episode 1.
I am trying to acquire temperature measurement through a 4w rtd with agilent 34970a. Keysight technologies agilent technologies 34970a data. Example programs are included with most instrument driver downloads. Keysights benchvue daq control and analysis app is available for use with the daq970a, 34970a, 34972a and 34980a. Agilent 34970a continuous scanning ni community national. Learn how to configure the 34970a for rs232 communication. Choose from eight optional plugin modules to create a compact data logger, fullfeatured data. Introduction to the 34970a instrument driver an instrument driver is a set of software routines that control a programmable instrument.
How can i make ni labview communicate with my keysight. Le modele agilent technologies 34970a34972a associe des possibilites. The agilent 34970a consists of a threeslot mainframe with a builtin 6 12 digit digital multimeter option 001, removes the dmm. This example assumes the users pc has a national instruments gpib board. Automating keysight instruements with labview episode 3 using. Plug and play driver installation instructions learn how to install your plug and play instrument driver. An instrument driver is a set of software routines that control a programmable instrument. The tms9914 was a standard peripheral device nec offered a similar product, the upd7210. View and download agilent technologies 34970a quick reference manual online. The instrument address check failed or the instrument did not return an idn string or something. Ni visa provides support for customers using ethernet, gpib, serial, usb, and other types of instruments.
Test and measurement basics daq episode 7 connecting the 34970a to pc via gpib interface duration. Nov 17, 2019 agilent a ivi driver top freeware programs i understand you can do this using labview. Dec 05, 2015 instrument driver network idnet find, download, or submit a driver to communicate with thirdparty instruments. This video shows how to use a labview driver to communicate with your keysight instrument. Use keysight hp agilent gpib devices with ni software.